JE-Y(ST)Y...BD EB 20 X 2 X 0.8

Low Frequency (LF) data transmission cable, 20 Pair, Overall Screened, Polyvinyl chloride (PVC) outer sheath colour Blue for Intrinsic Safety Applications, fixed and occasional flexing installation, indoor and in plaster use, conductor size of 0.8 ø mm, 225 V (Not for power application), 16mm OD, Flame Retardant to IEC 60332-1-2, Approvals: Fire protection.

Rs701.38
Out of stock
Article No.
0034125
(Rs701.38/M)
Inclusive of tax
Product information (PDF)

Temporarily Out of Stock

  • JE-Y(ST)Y…BD EB installation cable for industrial electronics, solid conductor/ stationary use, pairs, screened/ static foil, blue/ intrinsically safe circuits

Benefits

  • Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC).
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)

Application Range

  • Connection cable for fixed installation in industrial control systems, as required in measurement, control, signalling and data applications
  • Industrial electronics
  • For fixed installation on and under plaster, in dry and damp rooms
  • For outdoor use this cable should be installed under plaster only

Norm References / Approvals

  • In accordance with DIN VDE 0815type JE-Y(ST)Y...BD

Product Make-Up

  • Solid bare copper conductor
  • Core insulation made of PVC
  • 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.8 as star quad cable)
  • Foil wrapping, static screening made of aluminium-laminated plastic film with copper drain wire
  • Outer sheath made of PVCOuter sheath colour: sky blue (RAL 5015)

Product Features

  • Flame-retardant according IEC 60332-1-2
  • The 2-pair version (2x2x0.8) is twisted into a star quad
  • JE-Y(ST)Y...BD EB:For intrinsically safe circuits (type of protection i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2

Minimum Bending Radius

  • Fixed installation: 6 x outer diameter

Temperature Range

  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -30°C to +70°C

Core Identification Code

  • according to VDE 0815, refer to Appendix T10

Test Voltage

  • Core/Core: 1000 V
  • Core/screen: 2000 V

Coupling

  • approx. 200 pF/100 m

Loop Resistance

  • max. 73.2 Ohm/km

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000829
  • ETIM 5.0 Class-Description: Signal-/telecommunications cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000829
  • ETIM 6.0 Class-Description: Signal-/telecommunications cable

All articles from JE-Y(ST)Y...BD EB

Article number Number of cores and cable diameter (mm) Outer diameter [mm] Copper index (kg/km) Weight (kg/km) Action
0034120 2 x 2 x 0.8 6.0 25.0 60.0
0034121 4 x 2 x 0.8 8.5 45.0 100.0
0034122 8 x 2 x 0.8 11.0 85.0 165.0
0034123 12 x 2 x 0.8 13.0 126.0 240.0
0034125 20 x 2 x 0.8 16.0 206.0 360.0
* 0034126 32 x 2 x 0.8 20.0 327.0 555.0
ACCESSORIES