JE-Y(ST)Y...BD EB 4 X 2 X 0.8

Low Frequency (LF) data transmission cable, 4 Pair, Overall Screened, Polyvinyl chloride (PVC) outer sheath colour Blue for Intrinsic Safety Applications, fixed and occasional flexing installation, indoor and in plaster use, conductor size of 0.8 ø mm, 225 V (Not for power application), 8.5mm OD, Flame Retardant to IEC 60332-1-2, Approvals: Fire protection.

Rs162.61
Out of stock
Article No.
0034121
(Rs162.61/M)
Inclusive of tax
Product information (PDF)

Temporarily Out of Stock

  • JE-Y(ST)Y…BD EB installation cable for industrial electronics, solid conductor/ stationary use, pairs, screened/ static foil, blue/ intrinsically safe circuits

Benefits

  • Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC).
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)

Application Range

  • Connection cable for fixed installation in industrial control systems, as required in measurement, control, signalling and data applications
  • Industrial electronics
  • For fixed installation on and under plaster, in dry and damp rooms
  • For outdoor use this cable should be installed under plaster only

Norm References / Approvals

  • In accordance with DIN VDE 0815type JE-Y(ST)Y...BD

Product Make-Up

  • Solid bare copper conductor
  • Core insulation made of PVC
  • 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.8 as star quad cable)
  • Foil wrapping, static screening made of aluminium-laminated plastic film with copper drain wire
  • Outer sheath made of PVCOuter sheath colour: sky blue (RAL 5015)

Product Features

  • Flame-retardant according IEC 60332-1-2
  • The 2-pair version (2x2x0.8) is twisted into a star quad
  • JE-Y(ST)Y...BD EB:For intrinsically safe circuits (type of protection i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2

Minimum Bending Radius

  • Fixed installation: 6 x outer diameter

Temperature Range

  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -30°C to +70°C

Core Identification Code

  • according to VDE 0815, refer to Appendix T10

Test Voltage

  • Core/Core: 1000 V
  • Core/screen: 2000 V

Coupling

  • approx. 200 pF/100 m

Loop Resistance

  • max. 73.2 Ohm/km

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000829
  • ETIM 5.0 Class-Description: Signal-/telecommunications cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000829
  • ETIM 6.0 Class-Description: Signal-/telecommunications cable

All articles from JE-Y(ST)Y...BD EB

Article number Number of cores and cable diameter (mm) Outer diameter [mm] Copper index (kg/km) Weight (kg/km) Action
0034120 2 x 2 x 0.8 6.0 25.0 60.0
0034121 4 x 2 x 0.8 8.5 45.0 100.0
0034122 8 x 2 x 0.8 11.0 85.0 165.0
0034123 12 x 2 x 0.8 13.0 126.0 240.0
0034125 20 x 2 x 0.8 16.0 206.0 360.0
0034126 32 x 2 x 0.8 20.0 327.0 555.0
ACCESSORIES